Time stamped list mode data from gamma-ray spectroscopic measurements on 47 nuclear fuel assemblies performed at Clab, Sweden, September 2016 through March 2019

SND-ID: 2024-303. Version: 1. DOI: https://doi.org/10.57804/2w41-0824

Citering

Skapare/primärforskare

Peter Jansson - Uppsala universitet, Institutionen för fysik och astronomi, Tillämpad kärnfysik orcid

Martin Bengtsson - Svensk Kärnbränslehantering

Ulrika Bäckström - Svensk Kärnbränslehantering

Sophie Grape - Uppsala universitet, Institutionen för fysik och astronomi, Tillämpad kärnfysik orcid

Erik Branger - Uppsala universitet, Institutionen för fysik och astronomi, Tillämpad kärnfysik orcid

... Visa mer..

Peter Jansson - Uppsala universitet, Institutionen för fysik och astronomi, Tillämpad kärnfysik orcid

Martin Bengtsson - Svensk Kärnbränslehantering

Ulrika Bäckström - Svensk Kärnbränslehantering

Sophie Grape - Uppsala universitet, Institutionen för fysik och astronomi, Tillämpad kärnfysik orcid

Erik Branger - Uppsala universitet, Institutionen för fysik och astronomi, Tillämpad kärnfysik orcid

Anders Sjöland - Svensk Kärnbränslehantering

Visa mindre..

Forskningshuvudman

Uppsala universitet rorId

Beskrivning

Data were collected by saving list-mode detector data during acquisitions. Two types of measurements were performed; Measurements with nuclear fuel assemblies present and background measurements without the fuel assemblies. Background measurements were performed in sequences of about 10 min acquisitions. The fuel assemblies were positioned in the water pool and axially moved during acquisition in front of a collimator built into the pool wall, rotated so that one of its four corners points towards the detector. The 137Cs calibration source was positioned along the centre line of the collimator slit both during background and fuel measurements. The detector and associated electronics were located in a room adjacent to the pool.

Measurement data is saved in a text format. The text format is structured as a measurement header, followed by a sequence of one or more meta-batches. Each meta-batch is structured as a sequence of one or more event data batches. Each event data batch is structured as an event batch header, followed by one or more event data lines and an event batch footer.

Datasetet h

... Visa mer..
Data were collected by saving list-mode detector data during acquisitions. Two types of measurements were performed; Measurements with nuclear fuel assemblies present and background measurements without the fuel assemblies. Background measurements were performed in sequences of about 10 min acquisitions. The fuel assemblies were positioned in the water pool and axially moved during acquisition in front of a collimator built into the pool wall, rotated so that one of its four corners points towards the detector. The 137Cs calibration source was positioned along the centre line of the collimator slit both during background and fuel measurements. The detector and associated electronics were located in a room adjacent to the pool.

Measurement data is saved in a text format. The text format is structured as a measurement header, followed by a sequence of one or more meta-batches. Each meta-batch is structured as a sequence of one or more event data batches. Each event data batch is structured as an event batch header, followed by one or more event data lines and an event batch footer.

Datasetet har ursprungligen publicerats i DiVA och flyttades över till SND 2024. Visa mindre..

Data innefattar personuppgifter

Nej

Språk

Metod och utfall
Datainsamling
Geografisk täckning
Administrativ information

Identifierare

Ämnesområde och nyckelord

Forskningsområde

Subatomär fysik (Standard för svensk indelning av forskningsämnen 2011)

Publikationer
Publicerad: 2024-06-25